Replacing a Cast Hatch Actuator or Escape Handle
Items Needed to Complete This Job
- 1/4” pin punch (6.35 mm)
- Hammer
- Sturdy work surface supporting the center shaft solidly
- Clean cloth
- Freeman Hatch Actuator (aluminum or 316 stainless steel)
- Freeman Escape Handle Assembly
- New knurled pin (Knurl Pin – supplied in shipment with the part)
- CRC Ceramic Paste Anti-Seize or Tef-Gel (pin thread anti-seize)
- Vickers Oils BIOGREASE EP2 (linkage and shaft contact grease)
Step-by-Step Procedure
Support center shaft and drive out the existing pin
Fully support the center shaft of the hatch on a sturdy work surface. Using a 1/4” pin punch, drive the pin out of the actuator or escape handle on the bottom of the shaft.
Remove actuator or handle
Remove the old actuator or escape handle from the shaft. Clean the shaft surface and inspect the cross-bore for burrs.
Coat the new knurled pin with lubricant / anti-seize
Coat the replacement knurled pin with CRC Ceramic Paste or Tef-Gel lubricant to prevent thread galling and galvanic seizure.
Slide replacement actuator or escape handle onto shaft
Slide the replacement actuator or escape handle onto the shaft.
Align mounting holes
Align the cross hole in the center shaft with the hole in the actuator or escape handle.
Support center shaft and drive in new pin
Again, carefully support the center shaft solidly from underneath while driving the new knurled pin into the actuator or escape handle.